AUTOSAR-AGENT-SKILLS ← Overview GitHub

arxml-dbc-consistency

Cross-validates AUTOSAR Classic ECU configuration — Com, PduR, CanIf and CanDrv ECUC containers — against a DBC communication matrix. 26 check codes, Python standard library only.

v1.1.226 check codes 0 dependenciesMIT

Commands

python skills/arxml-dbc-consistency/scripts/arxml_dbc_check.py probe  ecuconfig.xml
python skills/arxml-dbc-consistency/scripts/arxml_dbc_check.py check  ecuconfig.xml matrix.dbc
python skills/arxml-dbc-consistency/scripts/arxml_dbc_check.py matrix ecuconfig.xml matrix.dbc --csv inventory.csv
python skills/arxml-dbc-consistency/scripts/arxml_dbc_check.py selftest

probe inspects structure first — vendor container names, parameter names and where signals are mounted vary enormously. check then compares. Exit code is 1 on error, so it drops straight into CI.

Why name matching cannot work

In a real configuration Com and CanIf are not directly connected; the only sound binding key is the CAN ID:

DBC frame ──CanId──> CanIf PDU ──CanIfXxxPduRef──> EcuC Pdu(X)
                        ──PduR routing──> EcuC Pdu(COM_X)
                        ──ComPduIdRef──> Com IPdu

IPDU_COM_TP_Param has nothing name-wise in common with the DBC frame Diag_CalData, yet they are the same link (COM_TP_Param → CanTp_TP_Param → 0x9B). Joining by name is guaranteed wrong.

There is exactly one correct bit-geometry formula

AUTOSAR's ComBitPosition always stores the signal LSB (flat numbering, bit 0 = LSB of byte 0), regardless of byte order. DBC numbers Motorola signals in sawtooth form and stores the MSB, so first walk back len-1 steps:

def motorola_msb_from_lsb(lsb, length):
    pos = lsb
    for _ in range(length - 1):
        pos = pos - 15 if pos % 8 == 7 else pos + 1
    return pos

Measured on a production project: 215/215 signals matched. An earlier version assumed "MSB and LSB schools coexist", tried both and accepted either — that design is wrong: a genuine error gets whitewashed by a coincidental match, and the measured hit rate was only 153/215.

A whole-network matrix is not one ECU's view

A DBC may describe only this ECU (a dozen frames), or the entire network (hundreds of frames, many other nodes under BU_:). In the latter, most frames belong to other parties and this ECU should have no configuration for them at all. The script decides frame by frame — "sender is this ECU, or some signal's receiver includes this ECU" — and only raises error on relevant frames.

On an 11-node, 91-frame matrix, the old "every frame must be configured" assumption produced 99 false errors and buried all 6 real defects. False positives are worse than misses: nobody reads past line one hundred.

Bus coverage

An ARXML often drives several CAN buses at once. The script walks back through CanIfBufferCfg → CanIfHthCfg → CanIfHthCanCtrlIdRef to identify the bus and computes each bus's hit rate against the DBC: ≥20% is compared normally, <20% is skipped wholesale with an info line.